Ul1061 Wire

ul1061 wire is a single core PVC insulated hook-up wire, also a very common item which often has safe ready stock. Its normal size range is from 30 awg to 14 awg. It can be widely used in electric toys, electronic and electrical equipment and so on.

●Parameters

Rated temperature

80℃

Rated voltage

300V

Reference standard

UL758,UL1581,CSA C22.2No.210.2

Type

Single core hook-up wire

Material

Copper conductor, PVC insulation

Flame retardant grade

UL VW-1,CSA FT1 and JQA -F-Mark flame test


20190703133341


●Product description

Solid or stranded ,tinned or bare copper conductor 30~14AWG

PVC insulation ,comply with ROHS environmental standard

Uniform insulation thickness to ensure easy stripping and cutting

For general purpose internal wiring of appliance


●Detailed data

CONDUCTOR

INSULATION

MAX.COND.

RESISTANCE (Ω/km,20℃,DC)

DIELECTRIC

STRENGTH

(VAC,1min)

AWG

CONSTRUCTION

(No./mm)

DIA.

(mm)

THICKNESS

(mm)

O.D.

(mm)

30

1/0.254

7/0.10

0.25

0.30

0.25

0.25

0.75

0.80

361

381

2,000

28

1/0.32

7/0.127

7/0.127OS-1*

0.32

0.38

0.38

0.27

0.26
0.26

0.85

0.90
0.90

227

239

239

2,000

26

1/0.404

7/0.16

7/0.16 OS-1*

0.40

0.48

0.48

0.25

0.26
0.26

0.90

1.00
1.00

143

150

150

2,000

24

1/0.511

7/0.20

7/0.20OS-1*

0.51

0.60

0.60

0.25

0.25

0.25

1.00

1.10
1.10

89.3

94.2

94.2

2,000

22

1/0.643

7/0.254

7/0.254 OS-1*

0.64

0.76

0.76

0.25

0.27
0.27

1.15

1.30
1.30

56.4

59.4

59.4

2,000

20

1/0.813

7/0.32

7/0.32OS-1*

0.81

0.96

0.96

0.27

0.27
0.27

1.35

1.50
1.50

35.2

36.7

36.7

2,000

18

1/1.024

16/0.254

7/0.404OS-1*

1.02

1.17

1.20

0.27

0.31
0.30

1.55

1.80
1.80

22.2

23.2

23.2

2,000

16

1/1.29

26/0.254

1.29

1.49

0.25

0.31

1.80

2.10

14.0

14.6

2,000


●Application

This item is widely used in the interior of electronic or electrical equipment, especially household appliances like air-conditioner, washing machine, refrigerator, TV, micrawave, cooker, coffee machine and so on.


●Production details

Its processing technology usually includes three steps: PVC granulation, conductor stranding and insulation extrusion. The quality department strictly inspects and controls the feeding, processing and finished products.

●Packing

According to the final diameter values of different AWG sizes, the SPQ of ul1061 wire is approximately 1000ft~2000ft/roll.


●Advantages

ROHS&REACH promised, adding strength to environmental protection.

Our company has passed product certifications of over 10 countries, such as UL, CSA, PSE, VDE, KTL, SAA, CCC and etc.

●FAQ

Q: Whether your products be compliance with ROHS?

A: Yes, all raw materials which we using are totally compliance with ROHS lastest requirement.

Q: Whether your products be compliance with REACH?

A: Yes, all raw materials which we using are totally compliance with REACH lastest requirement.

Q: Can we get sample from you? Is it free?

A: Surely you can get sample from us, but whethet it is free or not to be decided by stock situation.


Previous: Ul1028 Hook-up Wire

Next: Ul Hook-up Wire